Lee Revell wrote:
[cut]Hey! great reply time! :)
> Try building JACK without --enable-optimize.
Hmmm... I don't remember having done that. Gotta try it. And in this
case I don't have to rebuild all the clients, do I?> Have you tried a different machine?
Yes, same results...
> Or changing the PCI latency settings?
Same as above.
Maybe the PCI latency settings i made are not correct, here they are:
#enough bandwidth for all devices
setpci -d *:* latency_timer=b0## max bandwidth for Delta44
setpci -s 00:0b.0 latency_timer=FFI also remember an old thread
http://sourceforge.net/mailarchive/message.php?msg_id=8422439
on calculating the right values for PCI latency for each card in the MB.
I remember having ended up following
http://www-128.ibm.com/developerworks/library/l-hw2.htmlciao
--
salvuz
POST FATA RESVRGO
Linux registered user #291700 | machine #174619
get counted on ---> http://counter.li.org/ <---